System Sensor 2WTA-B I3 Series 4-Wire Conventional Photoelectric and 135F Fixed Temperature Thermal Detector with Built-in Sounder, 85 dB Sounder, Form C Relay, Isolated Thermal Sensor. If the detector is in need of maintenance because its sensitivity has shifted outside the listed limits, the red LED blinks once every five seconds. NOTICE: This manual shall be left with the owner/user of this equipment. Ep. After some recent electrical work (new AC unit in the attic) the vista 20p shows fire trouble, and occasionally sets off the alarm. Explore System Sensor products including: AV Notification, Beam Smoke detection, CO detection, HVAC Smoke detection, spot smoke detection, relays, & modules. Copies of this 0
Please read thoroughly System Sensor manual A05-1003. 41F (5C) NIB!! Follow the steps in the Tech Bulletin below to check your current firmware version and update your device firmware if needed.. In wet or excessively humid areas, or next to bathrooms with showers. Ensure your FAAST device has the most up-to-date firmware. Enter a zip code, select a range, and choose a Distributor type to locate the nearest Distributor. 5.3 inches View a list of all System Sensor locations worldwide. The 2W -MOD2 can. System Sensor two-wire smoke detectors are marked with a compatibility identifier located on the label on the back of the product. If they are not just take a photo of the connections and land what is connected to the positive connection the new plates positive and same with the negative. further simplified by the incorporation of features compatible with drywall Remove power from alarm control unit or initiating device circuits before installing detectors. I recommend powering down the system and placing your system on test mode if monitored before swapping in the new smoke. The System Sensor 2W-B is a 2-wire smoke detector and a member of System Sensors i3 Series of photoelectric smoke detectors. or exclusion may not apply to you. 3. To view this information, simply choose a manufacturer and the appropriate model. . Consult the list to locate a control module for your specific fire alarm system. System Sensors intelligent and conventional modules are designed to help you meet a wide range of application requirements. (See Figure 4.). the removal of detectors before beginning construction or other dust producing activity. Near fresh air inlets or returns or excessively drafty areas. However, they may not completely prevent airborne dust Compatible with 12- or 24-volt systems. The i3 Series 2W-B uses drift compensation technology and smoothing algorithms which prevent the smoke detector from becoming too sensitive as dust accumulates. Maximum Initial *Assumes the panels alarm verification reset time is 10 seconds or less. RA400Z Remote Annunciator to be connected. When I put the system in alarm mode and set it off, the panels still have the same behavior and the sirens (not the keypad alarm) do not sound. Wired. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. These limits are designed to provide 7. They also answer your questions from the comfort of home or the office. Will these cover up a low voltage mudring? SMOKE In wet or excessively humid areas, or next to bathrooms with showers. A copy of this list is available from System Sensor upon request. NOTE: Before performing maintenance on the detector, notify the proper authorities that maintenance is being performed and the system will be temporarily out of service. HyperSpike speakers offer revolutionary sound quality and intelligibility for fire and life safety applications and their innovative designs exceed the highest standards in military and acoustic notification markets. Weight: Operating Temperature Range: Fill out our feedback form! The smoke alarm was perfectly compatible with my 24-year old house alarm system. unreasonable use, modifications, or alterations occurring after the date of manufacture. *Refer to Electrical Specifications for start-up time in conjunction with panel I am not of the exact model number of the existing 2-wire smoke detector so I cannot say for sure if the back plates are the same. Max. I have a Vista 6150 15P Control Panel and an old System Sensor 2312/24TB 4 wire Smoke/heat detector. Three-Year Limited Warranty 21. Product specifications subject to change without notice. I will say that it came packaged correctly and it functions as designed, would buy again. 9H2u*A^Xob`bd`SD+0 vEw
Insert a small screwdriver or allen wrench (0.18 max.) has been made tamper resistant, use a small screwdriver to depress the square : The 2W-B smoke detector works with most Honeywell alarm control panels including the VISTA-20P and VISTA-21iP as System Sensor is a subsidiary of Honeywell. 2009 System Sensor. The 2W-B smoke detector is not the typical conventional detector. To test this please remove AC power and set the panel into alarm mode to see if the battery will support the system and report back. Hold a smoldering punk stick or cotton wick at the side of the detector and Now it's easy to identify System Sensor bases that are compatible with individiual OEM detectors. 2W-B and 4W-B: may also have other rights which vary from state to state. What's the Best Place to Install a Smoke Detector. (For 2W-B and 2WT-B, panel must limit current) 23 mA 24 Volt Systems Condition Each i3 Series detector is supplied with a mounting base that can be Dimensions: 2.0" (51mm) H x 5.3" (127mm) Dia. NOTE: For the above tests, the detector will reset only after the power source Models 2W-B and 2WT-B also include an output that allows an optional Model RA400Z Remote Annunciator to be connected. detectors to the alarm control panel and accessory devices should be colorcoded to reduce the likelihood of wiring errors. I have a DSC alarm system that my current System Sensors are connected to and would I need to do anything special when I replace the old with the new other then reset the system? At a minimum, cleaning, Models 2W-B and 2WT-B are 2-wire photoelectric smoke detec-, tors; models 4W-B and 4WT-B are 4-wire photoelectric smoke, detectors. applicable state and local codes, and any special requirements of the local 45 This includes cleaning, maintenance or screen replacement. In order for this feature to work properly, the chamber must never be opened while power is applied to the smoke 15 Travis, with 4-wire smokes, you usually don't have to verify compatibility. DETECTOR 32 to 120F (0 to 49C) DIAMETER TOOL, Figure 5: Removing/Replacing Screen/Sensing Chamber You have been registered for product and offer updates. Test i3 Series detectors as follows: If the detector is within the listed sensitivity limits, the detectors red Min. detector. Start-up Time: 2. To remove the detector from the base once it Twisted pair may be used to provide additional protection against extraneous electrical interference. System Sensor shall have no liability. This includes cleaning, maintenance or screen replacement. Consult the list to locate a control module for your specific fire alarm system. for System Smoke Detectors, which provides detailed information on detector and workmanship under normal use and service for a period of three years from date of a 2W-MOD2 module. Near fresh air inlets or returns or excessively drafty areas. Therefore, System Sensor recommends try to correct the interference by one or more of the following measures: Table 2: Power-up Sequence for LED Status Indication* Height (including base): switch opening; push and hold. 2. Enter your email address and check your inbox. Locking Pin. list is available from System Sensor upon request. endstream
endobj
1001 0 obj
<>>>/EncryptMetadata false/Filter/Standard/Length 128/O(19[nMM\\.9rvXbp)/P -1036/R 4/StmF/StdCF/StrF/StdCF/U(bH;^Soe9ACM )/V 4>>
endobj
1002 0 obj
<>
endobj
1003 0 obj
<>/ExtGState<>/Font<>/ProcSet[/PDF/Text/ImageB]/XObject<>>>/Rotate 0/Type/Page>>
endobj
1004 0 obj
<>stream
Consult the dealer or an experienced radio/TV technician for help. All System Sensor i3 Series smoke detectors are designed for easy installation, advanced detection and fast inspection. PipeIQ guides users through the initial pipe layout and system configuration for a FAAST aspiration system. With. Freeze Trouble (Model 2WT-B and 4WT-B): In dusty, dirty, or insect-infested areas. System Sensor offers world-class fire detection and notification solutions System Sensor Founded in 1984, System Sensor is a global manufacturer of fire and life safety devices, specializing in smoke detection, carbon monoxide detection, and notification technology for world-wide applications. against extraneous electrical interference. mounted: Proper wire gauges should be used. Enter a zip code, select a range, and choose a Distributor type to locate the nearest Distributor. Loop Verification (models 2W-B and 2WT-B only) 2W-B and 2WT-B, connect detectors only to compatible alarm control panels as identified by System Sensor's compatibility chart. The calculated illumination is required to be at least 0.0375 lumens/ft2 at any point within the covered area. its listed sensitivity range, the green LED blinks once every five seconds. VIEW MODELS Beam Smoke Detection The screw terminals in the mounting base will accept 1422 gauge wire. When the smoke detector is normal the green LED will blink every five seconds. It will take approximately 80. seconds for the detector to finish the power-up cycle (see Table 2). Activate the light at the display. For two-wire models 2W-B and 2WT-B, connect detectors only to compatible alarm control panels as identified by System Sensors compatibility chart. I would like to replace it with similar 4 wire detector like the 4WT-B detector and wanted to check if they are compatible? The Companys obligation Figure 3b: Wiring Diagram, 4W-B and 4WT-B at the control panel or module. 4-Wire Smoke Detector with 135F Fixed Heat Sensor, 2-Wire Smoke Detector with Fixed Heat Sensor, System Sensor 2W-B, 2WT-B, 4W-B & 4WT-B - Installation Guide. 4. When using the System Sensor 2W-B two wire smoke detector with a VISTA-20P or VISTA-21iP alarm control panel, you should wire the smoke detector to zone one. 2W-B Datasheet (HTML) - Systemsensor advanced ideas. in the Style D initiating device circuit (IDC) configuration requires the use OVAL AREA OR AT THE The microprocessor allows the detector to automatically adjust its The EZ Walk loop test verifies the initiating loop wiring and provides Direct mount or to ceiling using drywall fasteners (Figure 2). Alarm, Red LED This includes cleaning. Fill out the form and we'll contact you shortly. System Sensor's product 2-wire compatibility listings are available onlinefor you to view and print out. The microprocessor, allows the detector to automatically adjust its sensitivity back, to the factory setting when it becomes more sensitive due to, contaminants settling in its chamber. Table 2: Power-up Sequence for LED Status Indication*, (if excessive electrical noise is present). Authorization number, send defective units postage prepaid to: System Sensor, Repair Subscirbe to specific System Sensor email communications. When performing maintenance on your smoke detector, simply turn the 2W-B head counter clockwise to remove it from the base. r^ lC-kr$EG_ KD/T=[ $y`j"lOmX LX6F(F;x*+yj#xgUB?fH"U*zN84Vz
D~m$y:67HqwZJ:RSYk4MU=';W(pg|s[pJTW/X
'@GWSYm
}Fs A The CLSS Tool Suite allows you to perform battery, voltage drop, and Db line loss calculations in a single desktop application. Department, RA #__________, 3825 Ohio Avenue, St. Charles, IL 60174. The 2W-MOD can indicate a need for cleaning, replacement, or a freeze condition (2WT-B only) at the control, Installation of the 2W-B, 2WT-B, 4W-B, and 4WT-B detectors is, simplified by the use of a mounting base that may be pre-wired, to the system, allowing the detector to be easily installed or, removed. WIRING DIAGRAMS FIGURE 3A: WIRING DIAGRAM, 2W-B AND 2WT-B 2 . When the detector is in the alarm mode, the red LED latches on. Replace the detector cover by placing it over the screen/sensing chamber 2.0 inches This feature is Additionally, to my comment below will the base of the unit likely fit the old base so I can just twist it into place after connecting the wires? Fire Alarm Systems | System Sensor L-series indoor horn/strobes System Sensor L-series indoor horn/ strobes www.boschsecurity.com u u Plug-in design with minimal intrusion into the back box u Field-selectable candela settings of 15 or 30 cd at 12 V or 15, 30, 75, 95, 110, 135, and 185 cd at 24 V u Horn rated at 88+ dBA at 16 V Rotary switch for horn tone and two volume settings The mounting base installation is further simplified by the incorporation of features compatible with drywall fasteners. *Refer to Electrical Specifications for start-up time in conjunction with panel alarm verification. MOD2 module (refer to installation manual D5 00-46-00), the 2W -B and 2WT -B. are capable of gener ating a "maintenance needed" signal. Smoke Alarm. prevent a system from responding properly in the event of a fire. In order for this feature, to work properly, the chamber must never be opened while. Cross-Reference: AV L-Series to SpectrAlert Advanced, Cross-Reference: Base/OEM Detector Compatibility, DOWNLOAD STROBE COVERAGE CALCULATION EXAMPLES AVFL220, DOWNLOAD CTA System Sensor Speaker GLL Files, DOWNLOAD SS BASE DETECTOR CROSS-REFERENCE, DOWNLOAD SS BASE DETECTOR CROSS-REFERENCE LEGACY. An overview of latest updates, essential resources, and webinars. 3825 Ohio Avenue
Max. needed" signal. 100 List Price. Light settings: The brightness sensor is activated, it automatically switches between daytime Models 2W-B and 2WT-B are 2-wire photoelectric smoke detectors; models 4W-B and 4WT-B are 4-wire photoelectric smoke detectors. Power must be removed from the detector power is applied to the smoke detector. 4. System Sensor - Technical Field Bulletin Life Expectancy of System Smoke Detectors - Dated 05/2012, Limitations of Fire Alarm Systems - Dated 5/13 Rev. 3. 3825 Ohio Avenue, St. Charles, Illinois 60174 tamper release tab, located on the skirt of the mounting base, and turn the Deciding Whether to Use 2-Wire or 4-Wire Smoke Detectors. Storage Temperature Range: However, you can also use the 2W-B smoke detector with other alarm control panels, but you should verify compatibility with the manufacturer of the alarm control panel first. To measure the detectors sensitivity, the i3 Series Model SENSRDR Infrared Sensitivity Reader tool (see Figure 4) should be used. Tamper-Resistant Feature No. Wait approximately six minutes before performing EZ Walk test. General CLSS Tool Suite Discontinued Product Finder AV Audio Samples: AV Tones Calculator: AV Strobe Coverage Calculator: Voltage Drop Calculator: Sound Pressure Loss Increase the separation between the equipment and receiver. Unfortunately we do not support fire panels like the 32FB. way to insure proper operation of 2-wire i3 smoke detectors (2W-B, 2WT-B, Ensure proper wiring and power is applied. The 2W-MOD can 1. 0.3 All wiring must be installed in compliance with the National Electrical Code, 130 Dust covers are an effective way to limit the entry of dust into the smoke detector sensing chamber. on the screen/sensing chamber with the arrow on the housing. Explore System Sensor like white papers, announcements, technical bulletins, case studies, and more. or system undergoing maintenance to prevent any unwanted alarms. Unlike traditional detection systems, Reflected Beam Smoke Detectors were designed for spacious rooms, open areas, and high ceilings; their innovative features make them popular choices for spaces like warehouses, atriums, arenas, and churches. Place detector on the base and rotate clockwise. are capable of generating a maintenance needed signal. It should be straightforward if you do not need to wire the back plate. Also known as: 2WTAB, BK-2WTAB. ld house alarm system. System Sensors AV notification devices are the most versatile, easy to install, and cohesive line of audible visual (AV) notification appliances in the industry. be used in lieu of the tests specified under Testing. A05-0395-007 4/09 #2132 SpectrAlert Advance Dimensions Model Description Wall Horn Strobes P2R* 2-Wire Horn Strobe, Standard cd, Red Turn on: 1. (if excessive electrical noise is present) 5. No. endstream
endobj
473 0 obj
<>
endobj
474 0 obj
<>
endobj
475 0 obj
<>
endobj
476 0 obj
<>
endobj
477 0 obj
<>
endobj
478 0 obj
<>stream
Wiring Installation Guidelines Reinstall the detector and test. Refer to These calculations are described in NFPA 72 and are to be provided to the authority having jurisdiction. Air conditioners, heaters, fans, and fresh air intakes and returns can drive smoke Two-Wire Compatibility. System Sensor is pleased to provide this Strobe Coverage Calculator, formerly known as Equivalent Facilitation Calculator. Models 2W-B and 2WT-B are 2-wire photoelectric smoke detectors; models SWITCH WITH A item 1 System Sensor 2W-B i3 Series 2-wire, Photoelectric Smoke Detector. Proper wire gauges should be used. In dusty, dirty, or insect-infested areas. optional Model RA400Z Remote Annunciator to be connected. Alarm Reset Time: All i3 Series detectors are designed to provide open area protection. Notify the proper authorities that the system is in operation. %%EOF
POWER . If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to 2W-B and 2WT-B, connect detectors only to compatible alarm control panels Access all of System Sensor's tools and software offerings. The cable companies often use a special adapter to monitor a VISTA-20P system as explained at https://www.alarmgrid.com/videos/how-to-safely-remove-an-icontrol-from-an-existing-system. The i3 Series heads and bases are keyed so that a 2-wire head will only mount to a 2-wire base, and a 4-wire head will only mount to a 4-wire base. Alarm Type. The device uses photoelectric technology to detect smoke, while the fixed heat sensor activates at temperatures of 135F and higher. Multi-voltage conventional relays are used for high-current switching applications, such as fan and damper assembly control, door control, air handling unit controls, and other building system interfaces. note describing the malfunction and suspected cause of failure. Consult NFPA 72, the local Authority Having Jurisdiction (AHJ), and/or applicable codes for specific information regarding the spacing and placement of smoke detectors. 1050 0 obj
<>stream
endstream
endobj
startxref
System Sensor webinars provide relevant and timely information on products, market trends, and legislation. Models 2W-B and 2WT-B also include an output that allows an optional Model List Price $134.00 Our Price $88.99 You Save $45.01 (34%) of this Warranty shall be limited to the repair or replacement of any part of the smoke See how you can simplify specification, configuration, and installation of your notification project - saving time and money in the process. Band Color. The System Sensor COSMO-2W is a best-in-class i4 Series combination CO/Smoke detector is a 2-Wire carbon monoxide (CO) and smoke detection technology in a single, system-connected device. I have since replaced the battery, which has resolved the smoke error. 20 mA 12 Volt Systems Normal (standby) We're here to provide technical support for System Sensor products and service. "), INSTALLATION AND MAINTENANCE INSTRUCTIONS, 3825 Ohio Avenue, St. Charles, Illinois 60174. Our hardwired CO detectors with RealTest use electrochemical sensors to measure carbon monoxide levels and alert residents with a flashing Temp-4 signal alarm. They were an easy mount adapted to our smoke detecting system. System Sensor's AV notification devices are one of the most versatile, easy to install, and cohesive audible visual (AV) notification appliances in the industry. Twisted pair may be used to provide additional protection Do you see that white unit anywhere in or near your 20P alarm panel? FREE delivery Mar 8 - 10. 2), and then install the detector. System Sensor two-wire smoke detectors are marked with a compatibility identifier located on the label on the back of the product. MFR PART # 2W-B SYSTEM SENSOR | 2W-B i3 Series Detector, 2-wire, 12/24 V DC, with Base MFR PART # 2W-B PART # 674092 Spec Sheet Email Print Minimum 1 Each In Stock Details References Shipping Description Installation ease. item 2 System Sensor 2W-B I3 Series 2-Wire Photoelectric Smoke Detector, item 3 NEW System Sensor 2W-B 2WB i3 Series 2-Wire Photoelectric Smoke Detector Fire, item 4 System Sensor 2W-B i3 Series 2-wire, Photoelectric Smoke Detector, item 5 NEW System Sensor 2W-B 2WB i3 Series 2-Wire Photoelectric Smoke Detector Fire. any latin characters (a-z, A-Z) any numbers (0-9) special characters ("-", "_" and ". Fill out our feedback form! Initial LED Status Indication. Improper connections can prevent a system from responding properly in the event of a fire. It will take approximately 80 seconds for the detector to finish the power-up cycle (see Table 2). System Sensor does not provide any design or engineering services. Developed and delivered by Honeywell industry experts, HBU training employs techniques and technologies to help your teams learn everything they can about our products. After all detectors have been installed, apply power to the alarm control heads and bases are clearly identified as either 2-wire or 4-wire. Podcast; Latest detector counterclockwise. System Sensors intelligent and conventional modules are designed to help you meet a wide range of application requirements. i3 series (4 pages), I3 series. item 8 System Sensor 2W-B i3 Series 2-wire, Photoelectric Smoke Detector, 5.0 out of 5 stars based on 9 product ratings. 3. In or near areas where particles of combustion are normally present 15 sec 15 sec I am very happy with the purchase and while I only needed one I bought 2 to have one in reserve. The i3 Series heads and bases are keyed so that a 2-wire head will only mount detector to be easily installed or removed. Access all of System Sensor's tools and software offerings. spacing, placement, zoning, wiring, and special applications. For two-wire models Ready to learn more? 3. In wet or excessively humid areas, or next to bathrooms with showers. 32 Degrees to 120 Degrees F. Battery Backup. General Technical details Weight & dimensions Operational conditions Power Power source AC/DC show more Frequently Asked Questions Can't find the answer to your question in the manual? and turning it clockwise until it snaps into place. CAUTION To stay in the know on upcoming news and announcements, subscribe. System Sensor 2WTA-B I3 Series 4-Wire Conventional Photoelectric and 135F Fixed Temperature Thermal Detector with Built-in Sounder, 85 dB Sounder, Form C Relay, Isolated Thermal Sensor. The screw terminals in the mounting base will accept 1422 gauge wire. the use of a mounting base that may be pre-wired to the system, allowing the ABOUT US Updates 4.8 out of 5 stars based on 20 product ratings, 4.8 out of 5 stars based on 166 product ratings, 4.9 out of 5 stars based on 174 product ratings, 4.8 out of 5 stars based on 175 product ratings, 4.8 out of 5 stars based on 190 product ratings, 5.0 out of 5 stars based on 1 product rating. Improper connections can The System Sensor 2W-B smoke detector has a sensing chamber that that will become dirty with dust over time. NIB!! It should connect the same exact way. Power-up Are a Smoke Alarm and a Smoke Detector The Same Thing? NOTICE: This manual shall be left with the owner/user of this equipment. 46 | Microsoft VP Marcus Fontoura on Architecting Azure, the "World's Computer" 0:00 / 0:00. Leave everything as is at the panel and simply replace the smoke detector itself. indicate a need for cleaning, replacement, or a freeze condition (2WT-B only) Notify the proper authorities when the system is back in service. Users of this calculator are solely responsible for their own selection and use of products based upon information contained in this calculator and any calculations from this calculator. for use with i3 Series compatible control panels or the i3 Series 2W-MOD module only. View a list of all System Sensor locations worldwide. Subscirbe to specific System Sensor email communications. Connectivity. NOTE: T models must be used with compatible UL Listed panels only. However, there is no guarantee that interference will not occur in a particular installation. They also answer your questions from the comfort of home or the office. Verified purchase: Yes | Condition: Pre-owned. If the detector still fails, it should be replaced. Ripple Voltage: Wiring Diagrams Ready to learn more? System Sensor is not selling, supporting or endorsing AFMGs EASE Evac voice evacuation software. FireAlarm.com is always at the forefront of the fire & life safety industry offering the most diverse selection of technologies, offerings, and services - all for you to take advantage of FireAlarm.com is able to offer everything from Fire Alarm System Installation and Security Camera Surveillance, all the way to 24/7/365 Central Station Monitoring and Cellular Signal Transmission . When the alarm goes off, both keypads seem like they short out for a second (the display panel goes blank the ready and arm lights flash, and it makes a weird beeping noise) then starts the alarm tone at the keypads only. Preview PDF Download HTML 2W-B Datasheet (PDF) - Systemsensor advanced ideas. - 2W- B More results Similar Description - 2W-B More results DSC NEO: System Sensor 2-wire smoke wiring and programming This video showcases the wiring and programming for 2-wire smokes on a DSC NEO security system. Notify the proper authorities when the system is back in service. Smoke detectors are not to be used with detector guards unless the combination has been evaluated and found suitable for that purpose. sensitivity back to the factory setting when it becomes more sensitive due to tightening the screw to secure the wire in place. 4. When used with an i3 Series compatible control panel or the i3 Series 2WMOD module (refer to installation manual D500-46-00), the 2W-B and 2WT-B A. Peak Standby Current: Start-up Capacitance: CHAMBER OPENING The conductors used to connect smoke detectors to the alarm control panel and accessory devices should be color-coded to reduce the likelihood of wiring errors. The calculation points are in the horizontal and vertical planes in 5 degree increments per UL 1971. System Sensors AV notification devices are the most versatile, easy to install, and cohesive line of audible visual (AV) notification appliances in the industry. 1. System Sensor 2451 A Photo B401B / B406B / DH-400 / B110LP / B116LP A 120 System Sensor 2451TH A Photo / Therm.